1.8
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up.
1.8.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Status
Power
RM
ACA
I2
I1
LED
Display
Power Supply voltage
Status Device Status
RM
Ring Manager
ACA
Storage medium
ACA
42
Color Activity
—
none
yellow Lights up
flashes 4 times
a period
green Lights up
—
none
green Lights up
red
Lights up
Flashes 1 time
a period
flashes 4 times
a period
—
none
green Lights up
Flashes 1 time
a period
yellow Lights up
—
none
green Lights up
Flashes 3
times a period
yellow Lights up
Installation MSP30/32/40/42 and MSM20/22/24/40/42/46/50
Meaning
Supply voltage is too low
Device variants with redundant power
supply:
Supply voltage 1 or 2 is on
Software update is running. Maintain the
power supply.
Device variants with redundant power
supply:
Supply voltage 1 and 2 is on.
Device variants with single power supply:
Supply voltage is on
Device is starting and/or is not ready for
operation
Device is ready for operation.
Characteristics can be configured
Device is ready for operation.
Device has detected at least one error in the
monitoring results
The boot parameters used when the device
has been started differ from the boot
parameters saved.
Start the device again.
Device has detected a multiple IP address
No redundancy configured
Redundancy exists
Device is reporting an incorrect
configuration of the RM function
No redundancy exists
ACA storage medium not connected
ACA storage medium connected
Device writes to/reads from the storage
medium
ACA storage medium inoperative
Release 12 06/2018