2.Disable steppers operation: Press the knob to enter the main menu, select"Prepare"→"Disable
steppers".
3.Manual leveling:Move the extruder to the heating bed, and observe the distance between the extruder
and the heating bed from the front of the machine. if the distance between the extruder and the four
corners of the heating bed is 0.1 mm ( using a piece of A4 paper to assist leveling, A4 paper can pass
through the gap and feel slight resistance ), leveling is not required. If the distance between the
extruder and the four corners of the heating bed is greater than or less than 0.1 mm, adjust according to
step 4.
The distance between the
extruder and heating bed
page23of36