1.3) TIME ALARM = P1.3
Press
to enable the parameter programming
VV.V = Value of P1.3 TIME ALARM parameter to be associated to the article
setup. It indicates the maximum time (in seconds) during which the
tension value may exit from the tolerance range set by the 1.2) ERR
TENSION parameter. You can disable (OFF) or re-enable this feature by
pressing
Choose the desired value using
[allowed values: 0.1 to 10 sec.].
Press
to move to the next parameter.
1.4) TENS INC-DEC = P1.4
Press
to enable the parameter programming
VV.V = Value of parameter P1.4 INC-DEC TENSION parameter to be
associated to the article setup. It indicates the increment/decrement
resolution of the Tension graduated by the external INC/DEC command
pulses..
Choose the desired value using
[allowed values: 0.1 to 10 grams].
Press
to move to the next parameter.
1.5) METR INC-DEC (Available on SMART KTF-2000 only)
This parameter allows you to automatically graduate the yarn winding tension on
the bobbin at predefined intervals of meters, rather than using external INC-DEC
signals.
In particular, this parameter defines every how many meters the yarn tension
(MAIN TENSION) must be either incremented or decremented by the fixed
amount declared with the previous parameter 1.4) TENS INC-DEC.
When reaching the TARGET defined in 1.6) METR TARGET, the automatic
graduation is reset.
This feature allows you to change the softness of the bobbins during the rewinding
process, to make the dye-works easier, and it may help to obtain perfectly shaped
bobbins.