Industrial Electronic Devices

LEDS:

The device has got five LEDs that are used to give information of the functioning status.
The various meanings of the LEDs are described in the table below.
LED
1: Device State (green)
2: IO-Link comm. (green)
3: CAN comm. (green)
4: Error state (green)
5: Ethernet Link (green)
ADFweb.com Srl – IT31010 – Mareno – Treviso
Normal Mode
Blinks slowly (~1Hz)
Flashing: IO-Link communication
OFF: No IO-Link communication
Flashing: CAN communication
OFF: No CAN communication
ON: at least one IO-Link device is not communicating
OFF: No errors are present
ON: Ethernet cable connected
OFF: Ethernet cable not connected
User Manual IO-Link / CAN
Document code: MN67866_ENG
Revision 1.000
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in progress
ON: Ethernet cable connected
OFF: Ethernet cable not connected