ADF Web HD67873-A1-2A User Manual

Io-link / mqtt - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
IO-Link / MQTT - Converter
(Order Code: HD67873-A1-2A, HD67873-A1-4A,
HD67873-A1-2B, HD67873-A1-2A-2B)
for Website information:
www.adfweb.com/?Product=HD67873
for Price information:
www.adfweb.com/?Price=HD67873-A1-2A
www.adfweb.com/?Price=HD67873-A1-4A
www.adfweb.com/?Price=HD67873-A1-2B
www.adfweb.com/?Price=HD67873-A1-2A-2B
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual IO-Link / MQTT
Document code: MN67873_ENG
Revision 1.000
For others IO-Link devices, see also the following links:
IO-Link from/to ...
www.adfweb.com?Product=HD67860
www.adfweb.com?Product=HD67861
www.adfweb.com?Product=HD67862
www.adfweb.com?Product=HD67864
www.adfweb.com?Product=HD67864
www.adfweb.com?Product=HD67865
www.adfweb.com?Product=HD67866
www.adfweb.com?Product=HD67867
www.adfweb.com?Product=HD67868
www.adfweb.com?Product=HD67869
www.adfweb.com?Product=HD67870
www.adfweb.com?Product=HD67871
www.adfweb.com?Product=HD67872
www.adfweb.com?Product=HD67874
www.adfweb.com?Product=HD67875
www.adfweb.com?Product=HD67876
www.adfweb.com?Product=HD67877
www.adfweb.com?Product=HD67878
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67876
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Page 1 of 41
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(BACnet Master)
(BACnet Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(NMEA0183)
(NMEA2000)
(PROFINET Slave)
(SNMP Manager)
(SNMP Agent)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67873-A1-2A and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67873-A1-2A

  • Page 1 Revision 1.000 Page 1 of 41 User Manual Revision 1.000 English IO-Link / MQTT - Converter (Order Code: HD67873-A1-2A, HD67873-A1-4A, HD67873-A1-2B, HD67873-A1-2A-2B) for Website information: www.adfweb.com/?Product=HD67873 For others IO-Link devices, see also the following links: for Price information: IO-Link from/to …...
  • Page 2: Table Of Contents

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 2 of 41 UPDATED DOCUMENTATION: INDEX: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 3 of 41 SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 4 of 41 EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 5 of 41 CONNECTION SCHEME: Figure 1a: Connection scheme for HD67873-A1-2A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 6 of 41 Figure 1b: Connection scheme for HD67873-A1-4A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 7 of 41 Figure 1c: Connection scheme for HD67873-A1-2B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 8 of 41 Figure 1d: Connection scheme for HD67873-A1-2A-2B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 9: Characteristics

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 9 of 41 CHARACTERISTICS: The HD67873-A1 is a IO-Link / MQTT converter. It allows the following characteristics: Up to 1440 bytes in reading and 1440 bytes in writing; Two-directional information between MQTT and IO-Link;...
  • Page 10: Power Supply

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 10 of 41 POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax HD67873-A1-xx Consumption at 24V DC: Device...
  • Page 11: Function Modes

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 11 of 41 FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 12: Leds

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 12 of 41 LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 13: Io-Link

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 13 of 41 IO-LINK IO-Link is the first globally standardized IO technology (IEC 61131-9) that communicates from the controller down to the lowest automation level. This universally applicable interface is a fieldbus-neutral point-to-point connection which uses standard unshielded cables. IO-Link sends all the sensor and actuator signals to the controller and in turn carries controller data to the sensor/actuator level with revolutionary consequences.
  • Page 14: Aux Power Supply

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 14 of 41 IO-L LASS IO-Link Class B devices uses 5 pins on connectors and they require an additional aux power supply used for the actuation. These devices are normally actuators.
  • Page 15: Ethernet

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 15 of 41 ETHERNET: The Ethernet connection must be made using Connector5 of HD67873-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 16: Use Of Compositor Sw67873

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 16 of 41 USE OF COMPOSITOR SW67873: To configure the Converter, use the available software that runs with Windows called SW67873. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 17: New Project / Open Project

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 17 of 41 NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “IO-Link / MQTT - Converter”...
  • Page 18: Software Options

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 18 of 41 SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 19 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 19 of 41 In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software. ADFweb.com Srl –...
  • Page 20: Set Communication

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 20 of 41 SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67873 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in different sections in order to define the different parameters of the converter: IO-Link...
  • Page 21 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 21 of 41 IO-L This section is used to define the main parameters of IO-Link line. The means of the fields are: In the fields “Select Device”...
  • Page 22 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 22 of 41 THERNET This section is used to define the general parameters of Ethernet. The means of the fields are: In the field “Ip Address” the IP address of the converter is defined; In the field “SubNet Mask”...
  • Page 23 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 23 of 41 If the field “Enable DHCP” is checked, the converter acts as DHCP Server for the Clients connected. If the option is enabled, in the fields “DHCP First IP Address”...
  • Page 24 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 24 of 41 TLS (T RANSPORT AYER ECURITY This section is used to define the parameters of TLS protocol. The means of the fields are: If the field “Enable TLS”...
  • Page 25: Io-Link Set Access

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 25 of 41 IO-LINK SET ACCESS: By Pressing the “IO-Link Set Access” button from the main window for SW67873 (Fig. 2) the window “IO-Link Set Access” appears (Fig. 4). This section is used to define the list of IO-Link variables accessible from MQTT side.
  • Page 26 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 26 of 41 In the “List of IO-Link Channel” section it is possible to configure all the IO-Link channels of the converter (Fig. 5). Figure 5: “List of IO-Link Channel” section The meanings of the fields are: In the field “Channels”...
  • Page 27 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 27 of 41 By clicking on “Insert IODD”, the window “IO-Link IODD Catalog” appears (Fig. 6). This section is used to select an IO-Link device. By clicking on “Add IODD”...
  • Page 28 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 28 of 41 The “Process Data” section is used to define the IO-Link process data to link to MQTT side (Fig. 7). Figure 7: “Process Data” section The meanings of the fields are: In the field “Id”...
  • Page 29 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 29 of 41 The “Device Function – Variables” section is used to define the IO-Link parameters to link to MQTT side (Fig. 8). The meanings of the fields are: In the field “Index”...
  • Page 30 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 30 of 41 In the field “TotBitLen” the bit length of the array to which the IO-Link parameter refers is defined; In the field “BitOff” the bit offset of the IO-Link parameter is defined; In the field “Default”...
  • Page 31 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 31 of 41 The “I/O Options” section is used to define how linking the data from IO-Link pin 2 and pin 4 to MQTT side (Fig. 9). Figure 9: “I/O Options”...
  • Page 32 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 32 of 41 The “Events” section is used to define the IO-LINK events to map on MQTT side (Fig. 10). Figure 10: “Events” section The meanings of the fields are: In the field “Code”...
  • Page 33 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 33 of 41 In “Device Identity” section (Fig.11) and “Transport Identity” section (Fig. 12), the main features of the selected IO-Link device are reported. These characteristics are read from the IODD file. Figure 11: “Transport Layers”...
  • Page 34: Mqtt Set Topic

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 34 of 41 MQTT SET TOPIC: By Pressing the “MQTT Set Topic” button from the main window for SW67873 (Fig. 2) the window “Set MQTT Topics” appears (Fig. 13). This section is used to define the MQTT topics where the converter will publish the data from IO-Link and the topic that the converter will subscribes for writing the data to IO-Link.
  • Page 35 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 35 of 41 If the field “On CMD” is checked, the converter publishes the topic when a new message from IO-Link is received; If the field “On Timer”...
  • Page 36: Update Device

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 36 of 41 UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 37 User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 37 of 41 Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67873 device. Warning: If Fig. 15 appears when you try to do the Update try these points before seeking assistance: Try to repeat the operations for the updating;...
  • Page 38: Mechanical Dimensions

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 38 of 41 MECHANICAL DIMENSIONS: Figure 16: Mechanical dimensions scheme for HD67873-A1-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 39: Ordering Informations

    A: 1M, 35mm DIN Rail mounting Device Family HD67873: IO-Link / MQTT - Converter Order Code: HD67873-A1-2A IO-Link / MQTT – Converter (IO-Link ports: 2 x Class A) Order Code: HD67873-A1-4A IO-Link / MQTT – Converter (IO-Link ports: 4 x Class A) Order Code: HD67873-A1-2B IO-Link / MQTT –...
  • Page 40: Disclaimer

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 40 of 41 DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 41: Warranties And Technical Support

    User Manual IO-Link / MQTT Industrial Electronic Devices Document code: MN67873_ENG Revision 1.000 Page 41 of 41 WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67873-a1-4aHd67873-a1-2bHd67873-a1-2a-2b

Table of Contents