Rotex Controller Series Product Documentation page 54

Table of Contents

Advertisement

EbV
5.4.4.3.2
Separate Control Mode Nighttime Temperature
¦
ROOM NIGHT
c
o
16. 0
HC
5.4.4.3.3
Separate Control Mode Operating Mode Selection
OP. MODE
MC1
AUTOMATIC
MC1
5-34
Function:
In this operating mode, the relevant setpoint applies only to the selected HC (=
unmixed circuit), MC 1 (= mixed circuit 1) or MC 2 (= mixed circuit 2)
Setting:
Press ¦ key
Select the desired heating circuit, HC, MC-1 or MC-2, using the rotary pushbutton
Confirm the selected circuit by pressing the rotary pushbutton
Set the flashing room temperature value by turning the rotary pushbutton to the
desired value.
Confirm set value by pressing ¦ or î , press again: return to
display
Alternatively the value can be confirmed by automatic exit after the set time.
Function:
In separate operating mode, the selected program only applies to the previously
specified heating circuit.
Hence each heating circuit can be assigned its own operating mode.
Setting:
Press ¢ key
Select the desired heating circuit, HC, MC-1, MC-2 or DHW using the rotary
pushbutton
Confirm the selected circuit by pressing the rotary pushbutton
Set the flashing operating mode by turning the rotary pushbutton to the desired
value.
Confirm set value by pressing ¢ or î.
In short-term operating modes (Holiday, Absence, Party) set the desired target
value by turning the rotary pushbutton and confirm the set value as described
above.
Alternatively the value can be confirmed by automatic exit after the set time.