Rotex Controller Series Product Documentation page 5

Table of Contents

Advertisement

EbV
8.1.8.4
Modulation running time .................................................................. 8-8
8.1.8.5
Modulation starting time .................................................................. 8-9
8.1.8.6
Modulation starting load .................................................................. 8-9
8.1.9
8.1.10 Flue Gas Temperature Monitoring ....................................................... 8-10
8.1.11 Charging pump (CHP) ......................................................................... 8-11
8.1.12 Primary pump (PP) .............................................................................. 8-12
8.1.13 Boiler circuit pump ............................................................................... 8-12
8.1.14 Parallel heat generator release (PHR) ................................................. 8-13
8.1.15 Return control ...................................................................................... 8-13
8.1.15.1 Bypass pump (..VV..) .................................................................... 8-14
8.1.15.2 Return control through controlled flow mixing (..3..) ...................... 8-14
8.1.15.3 Indirect return control .................................................................... 8-15
8.1.16 When to activate boiler sensor 2 .......................................................... 8-15
8.1.17 External heat generator disable ........................................................... 8-16
temperature .......................................................................................... 8-16
8.1.19.1 DHW charging in boiler control MCBA .......................................... 8-16
8.1.19.2 DHW operation in combined devices ............................................ 8-17
8.1.20 Heat generator forced dissipation ........................................................ 8-18
8.1.21 Operating hours counter ...................................................................... 8-19
8.2
Heating circuit ............................................................................................. 8-19
8.2.1
Weather controlled heating operation .................................................. 8-19
8.2.1.1
Heating Characteristic Curve ........................................................ 8-19
8.2.1.2
Heating Circuit Reduced Mode ..................................................... 8-21
8.2.1.3
Heating system (exponent) ........................................................... 8-22
8.2.1.4
Heating Circuit Temperature Limitation ......................................... 8-22
8.2.1.5
Heating Circuit Parallel Shift ......................................................... 8-23
8.2.1.6
Heating circuit pump extended running time ................................. 8-23
8.2.1.7
Screed function ............................................................................. 8-24
8.2.2
8.2.2.1
Heating Circuit with Room influence ............................................. 8-26
8.2.2.2
Room factor heating circuit ........................................................... 8-27
8.2.2.3
Room Controller Heating Circuit ................................................... 8-28
8.2.2.4
Heating curve adaptation heating circuit ....................................... 8-28
8.2.2.5
Heating Circuit Room Frost Protection Limit ................................. 8-29
8.2.2.6
Room Thermostat Function (Room Temperature
Maximum Limit) ............................................................................. 8-29
8.2.2.7
Heating Circuit Switch-on Optimisation ......................................... 8-30
8.2.2.8
Optimisation for room controller (RC) ........................................... 8-31
8.2.3
Mixer control ........................................................................................ 8-31
8.2.3.1
Proportional band Xp .................................................................... 8-31
8.2.3.2
Integral action time Tn ................................................................... 8-31
8.2.3.3
Sample time Ta ............................................................................. 8-32
8.2.3.4
Actuator Running Time ................................................................. 8-32
8.2.4
Function Heating Limit ......................................................................... 8-34
8.3
Domestic hot water control (..B..) ............................................................... 8-34
8.3.1
DHW Tank Loading (DHW) .................................................................. 8-34
8.3.2
Circulation pump (CIR.) ....................................................................... 8-39
8.3.3
Electrical Heating Element (ELH) ........................................................ 8-40
8.4
Solar function (..VV..) .................................................................................. 8-40
Product documentation THETA NORM/UNIT
III

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Controller Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Theta normTheta unitTheta rsTheta rff

Table of Contents