Control Mode - Rotex Controller Series Product Documentation

Table of Contents

Advertisement

EbV
5.4.4.3

Control mode

Factory preset:
Setting range
Setting values:
5.4.4.3.1
Separate Control Mode Daytime Temperature
¥
ROOM DAY
o
20. 0
HC
1
1, 2
This parameter determines the control mode and has effects on the:
- Operating mode selected with the operating mode key ¢
- Daytime temperature selected with the "daytime temperature" key ¥
- Nighttime temperature selected with the "night-time temperature" key ¦
concerning the effect on the different heating circuits.
1: The selected setting (operating mode, daytime temperature,
night-time temperature) applies for all the heating circuits
2: Each heating circuit can be assigned its own setting (operating mode,
daytime temperature, night-time temperature).
Function:
In this operating mode, the relevant setpoint applies only to the selected HC (=
unmixed circuit), MC 1 (= mixed circuit 1) or MC 2 (= mixed circuit 2)
Setting:
Press ¥ key
Select the desired heating circuit, HC, MC-1 or MC-2, using the rotary pushbutton
Confirm the selected circuit by pressing the rotary pushbutton
Set the flashing room temperature value by turning the rotary pushbutton to the
desired value.
c
Confirm set value by pressing ¥ or î , press again: return to
Alternatively the value can be confirmed by automatic exit after the set time.
Product documentation THETA NORM/UNIT
standard display
5-33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Controller Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Theta normTheta unitTheta rsTheta rff

Table of Contents