Density Adjustment - Sony UP-D898MD Service Manual

Graphic printer
Hide thumbs Also See for UP-D898MD:
Table of Contents

Advertisement

3-1-6. Density Adjustment (Thermal Head Voltage Adjustment) and Set Serial
Number Setting
1. Type 120 in the edit box of "Head Voltage" of the Setup tab, and then click the [SET] button.
2. Select "STEP" from the drop-down list of "Test Pattern" of the Test Print tab.
3. Click the PRINT button of "Print".
The step pattern is printed.
4. Visually compare the density of the test print with that of the test print made before replacement in
each step.
When the density of the test print is different from that of test print made before replacement
(1) Click the [GET] button of "High Voltage" of the Setup tab.
The head voltage setting value is obtained.
(2) Change the obtained value by referring to the following, and then click the [SET] button.
The head voltage is adjusted.
. When the density is lower (lighter) than the reference sample: Increase the value.
. When the density is higher (darker) than the reference sample: Decrease the value.
(3) Print the step pattern according to steps 2 and 3.
(4) Visually compare the density of the test print with that of the test print made before replacement
in each step.
(5) Repeat steps (1) to (4) until the density of the test print becomes the same level as that of the test
print made before replacement.
3-8 (E)
[SET] button
Type 120.
UP-D898MD/X898MD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Up-x898md