5500 Series Power Operator - PULL SIDE Installation
Prepare Frame and Door for PULL Side Installation
Become familiar with operator components and fasteners. It is recommended that components remain in box
until installed. Verify there is minimum ceiling clearance for operator installation before proceeding. (Figure 1)
A. Prepare frame for operator.
1.
Verify frame reveal is maximum 1/8" (3mm).
(Figure 1)
2.
Determine if push or pull and if left hand or right
hand installation. (Figure 2)
NOTE: These steps are for PULL side only.
3.
Frame header MUST be flat / without twists.
Backplate of operator can be used as reference.
NOTE: If frame is not flat or is twisted, an
additional steel back plate or shimming is
required. Failure to mount unit properly can
result in improper function of operator.
4.
Using detailed template on page 15, prepare four
(4) holes for 1/4-20 machine screws or
14 x 2-3/4" sheet metal screws. Blind rivet nut
(by others) is suggested for unreinforced hollow
metal or aluminum frames. (Figure 3)
5.
For concealed mounted conduit (if applicable):
Prepare two (2) 7/8" (22mm) diameter holes
for conduit, for power input and for switch/
sensor wires.
NOTE: On new construction, these holes will
generally be drilled by frame supplier at their
shop or at time-of-install.
B. Prepare door for track.
1.
Using template on page 15, locate and
prepare holes in door for two (2) 12 x
1-3/4" sheet metal screws (Figure 4)
NOTE: Standard units are supplied
with sheet metal screws for 1-3/4"
(44mm) thick door. Sex nuts and
bolts (by others) are suggested
for unreinforced hollow metal or
aluminum doors.
Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9355-0001-020 Rev 1 08/20
2" (51mm)
Min. Frame
Face
1-3/4" (44mm) Min.
Door Thickness
2-1/4" (57mm) Max.
Figure 1
Right Hand
PULL
Figure 2
15-1/2
(394)
13-3/4
(349)
1-1/4
11-5/8
(32)
(295)
7/8
Ø (2x)
(23)
Right Hand Shown
Figure 3
9/16
7-5/16
(14)
(186)
Right Hand Shown
Figure 4
6-1/8" (15 mm)
6
Min. Ceiling
Clearance
Frame
Reveal
Push Side
Pull Side
Left Hand
PULL
13-1/16
(332)
7-5/8
(194)
1-1/2
1-1/4
(38)
(32)
1/4-20 Machine Screw or
No 14 Wood Screw (4x)
19-1/8
(486)
#12 (2x) In Door
5