Inverter Details; Wiring - Assa Abloy Norton 5500 Series Installation Instructions Manual

Power operator
Hide thumbs Also See for Norton 5500 Series:
Table of Contents

Advertisement

Adjustments made in the shaded area
should be performed by Authorized Factory
Personnel.
Operation:
Doors are normally closed.
Activating either switch will open
both doors.
Door will close after hold open
time delay has elapsed.
NOTE:
1.
Power input to Door Operator
Unit is at HOT/COM on terminal
strip shown 120VAC 60Hz.
2.
Door must be visible by person
operating activation switch(es).
12

Inverter Details

WARNING: 120 high volt potential present.
Make sure power is turned off during
installation procedure.
Standard Function With Switches Wiring
Door 1
Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
5500 Series Power Operator
Inverter Adjustments:
Use table to determine which POT to adjust based on function.
POT
Description
M/DLY
Motor Delay on Opening
Obstruction Detection on
OBSTR SENS
Open
P1
Closing Speed
H/O TM
Hold Open Time (5-30 Secs)
Motor Torque at Hold Open
H/O TQ
Position
P2
Opening Speed
Wall Switch, Card
Reader, Key Switch,
etc.
Door 2
HOT
COM
A1
A2
R1
R2
Wall Switch, Card
Reader, Key Switch,
etc.
Function
Clockwise:
Increase
Counter
Clockwise:
Decrease
Normally Open Momentary
dry contacts
Normally Open Momentary
dry contacts
80-9355-0001-020 Rev 1 08/20