Installation; General - Mira Realm Installation, Operation, Maintenance Manual

Table of Contents

Advertisement

Section
6

1. General

Read
the
section
Requirements first.
Important! Two flow regulators (grey housing
with black insert) are supplied with this
product. By fitting these in the inlet elbows
of the shower control (see diagram) this
product can be used with high pressure
systems. The regulator is fitted into the inlet
elbow of the shower control. Put the smaller
diameter in first and push until the flange
locates up against the internal shoulder.
Important! If they are to be retro-fitted the
inlet pipe will need to be shortened by the
thickness of the regulator flange to prevent
damage.
System
Unvented mains pressure
showers.
Mains pressurised instantaneous
hot water, heated from thermal
store, showers.
Gas heated showers
up to 30kW output.
Gas heated showers
above 30kW output.
Gravity fed showers
Pumped showers
¬
Note!
As there is no separate flow control, the regulators provide the most
satisfactory performance. The fitting of the hot regulator is optional and will determine
the strength of the spray from the shower head.

Installation

Installation
Diagram Reference
Compression
Olive
Flow
Regulator
Shower
Control
Section 5
2.4.
2.3.
2.2.
2.2.
2.1.
2.5.
Concealing
Plate
Compression
Nut
Regulators
Hot
Cold
ü
¬
ü
¬
ü
ü
ü
¬
ü
ü
Optional
13