Advertisement

MIRA REALM
THERMOSTATIC MIXER
INSTALLATION AND USER GUIDE
These instructions must be left with the user.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REALM and is the answer not in the manual?

Questions and answers

Summary of Contents for Mira REALM

  • Page 1 MIRA REALM THERMOSTATIC MIXER INSTALLATION AND USER GUIDE These instructions must be left with the user.
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please Recommended Usage take time to read this guide thoroughly, having Patents and Design Registration done so, keep it handy for future reference.
  • Page 3: Recommended Usage

    Euro: 07015846.4 the minimum achievable. USA: 2006-0124758-A1, 12/718 576 SAFETY : WARNINGS Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with manufacturer’s recommendations.
  • Page 4: Pack Contents

    PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that all of the parts are included. Mira Realm 4 x Compression Nuts (18 mm) 1 x Wall Bracket 4 x Olives (18 mm)
  • Page 5: Mira Realm With Diverter

    Mira Realm with Diverter 1 x Wall Bracket 1 x Showerhead 6 x Compression Nuts (18 mm) 2 x Hose Washers 1 x Shower Arm 6 x Olives (18 mm) 1 x Rigid Riser (Long) 2 x Compression Nuts (15 mm)
  • Page 6: Specifications

    SPECIFICATIONS Thermostatic Shut-down • Pressures For safety and comfort the thermostat will • shut off the mixing valve within 2 Seconds Max Static Pressure: 10 Bar. • if either supply fails (achieved only if the hot Max Maintained Pressure: 5 Bar. •...
  • Page 7: Dimensions

    Dimensions Mira Realm 1050 Mira Realm with Diverter 1006 All dimensions in mm...
  • Page 8: Installation

    required. INSTALLATION 3. Isolating valves must be installed close to the Mixer for ease of maintenance. Suitable Plumbing Systems 4. Pipework must be rigidly supported and avoid any strain on the connections. Gravity Fed: 5. Pipework dead-legs should be kept to a The thermostatic mixer must be fed from a cold minimum.
  • Page 9: Mira Realm

    Mira Realm Wall Plug 1. The thermostatic mixer can be installed with rear, rising or falling supply inlets. Decide on the most appropriate method for your installation, and if necessary, the inlet elbows can be swivelled to suit. 6 mm Drill 4.
  • Page 10 Wall Bracket Backplate Horizontal Arm Rigid Riser Pipe Showerhead Screws 8. For Rear Entry Supplies Only: Fit the concealing plates over the inlet pipes. Note! Apply silicone sealant to the back face of the flange. 14. Temporarily fit the rigid riser pipe and horizontal arm and wall bracket to the shower control outlet and mark the position of the wall Concealing Plate...
  • Page 11: Mira Realm With Diverter

    Mira Realm with Diverter 3. Fix the rigid riser pipes, diverter wall bracket and tighten the four compression fittings on 1. Refer to ‘Mira Realm, paragraphs 1 to 13’ to the shower control outlet and horizontal arm. install the mixer.
  • Page 12: Reversed Inlet Supplies

    7. Make sure that the two cartridge inlet seals are fitted and carefully push into the body, aligning The Mira Realm thermostatic mixer is supplied the cartridge lugs into the body slots. with inlet connections Hot - Left, Cold - Right Note! Check that the cartridge lug stamped as standard.
  • Page 13: Mira Realm With Diverter

    Mira Realm with Diverter COMMISSIONING The Mira Realm thermostatic mixer is a Maximum Temperature Setting thermostatic shower control with a single control lever for on/off and temperature control. Before using the shower the maximum temperature The Control Lever operates anti-clockwise in the...
  • Page 14: Fault Diagnosis

    10. Make sure that the hub is positioned fully FAULT DIAGNOSIS clockwise. 11. Refit the indicator trim in the same orientation If you require a Mira trained service engineer or that you removed it. agent, refer to section: ‘Customer Services’. 12. Fit the washer and the control lever.
  • Page 15: Maintenance

    12 months. If a malfunction occurs with the thermostatic cartridge then this will necessitate a complete cartridge replacement. Note! The cartridge contains no internally serviceable parts. If you require a Mira trained engineer or agent, Inlet Inlet Filter refer to section: ‘Customer Service’. Lubricants...
  • Page 16: Spare Parts

    SPARE PARTS Mira Realm 1735.114 Valve Seal Pack - Components Identified ‘A’ 1735.128 Screw Pack - Not Identified 1735.129 Component Pack - Not Identified 1735.123 Overhead Bracket 1735.124 Overhead Pipe 1735.121 Riser Pipe 1735.110 Outlet 1735.109 Connector Inlet Pack 162476 Backplate 1735.125...
  • Page 17: Mira Realm With Diverter

    Mira Realm with Diverter 1735.114 Valve Seal Pack - Components Identified ‘D’ 1735.115 Diverter Seal Pack - Components Identified ‘A’ 1735.116 Diverter Internals - Components Identified ‘B’ 1735.122 Riser Kit - Components Identified ‘C’ 1735.128 Screw Pack - Not Identified 1735.129 Component Pack - Not Identified...
  • Page 18: Accessories

    ACCESSORIES Genuine Mira accessories can be purchased direct from Mira Customer Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Wall Mounted Soap Dish Shower Seat Premium Shower Seat White - 1.1540.278...
  • Page 19: Notes

    NOTES...
  • Page 20: Customer Service

    filters) or where no fault has been found with guarantee period and beyond. You have the assurance of a the product. fully trained Mira Technician, genuine Mira spare parts and Water or electrical supply, waste and isolation issues. a 12 month guarantee on any chargeable work done.

Table of Contents

Save PDF