4-1. TROUBLESHOOTING GUIDE

Problem
POWER switch ON but fryer
completely inoperative
Shortening will not
heat but lights are on
Foaming or boiling
of shortening
Shortening will not
drain from frypot
Filter switch ON but
motor does not run
Or detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com, or
0512-89180262
or 1-800-417-8405 , 1-937-456-8405

SECTION 4. TROUBLESHOOTING

Cause
• Open circuit
• Open high limit
• circuit
• Water in shortening
• Improper or bad
shortening
• Improper filtering
• Improper rinsing after
cleaning the fryer
• Drain valve clogged
with crumbs
• Motor thermal
protector tripped
Correction
• Plug fryer in
• Check breaker or fuse at supply box
• Reset high limit per
• Drain valve open
• Turn drain valve handle to closed Position
• At end of cook cycle, drain
shortening and clean
• Use recommended shortening
• Refer to the procedure covering
filtering the shortening
• Clean and rinse the frypot, then
dry thoroughly
• Open valve, force cleaning
brush through drain
• Reset thermal switch per section
on Filter Pump Motor
Protector – Manual Reset