Filter Pump Motor Protector - Manual Reset (Optional Feature); Changing The Filter Envelope (Optional Feature) - Henny Penny OFE-141 Manual

Open fryer
Table of Contents

Advertisement

3-6. FILTER PUMP MOTOR
PROTECTOR – MANUAL RESET
(Optional Feature)
Figure 3-7
3-7. CHANGING THE FILTER
ENVELOPE (Optional Feature)
In the event it overheats, the filter pump motor is equipped with a
manual reset button located on the rear of the motor. After
waiting 5 minutes to allow the motor to cool, press the reset
button. It takes some effort to reset the motor. A screwdriver can
be used to help press reset button. Figure 3-3.
To prevent burns caused by splashing shortening, turn
the unit's filter PUMP switch to the OFF position
before resetting the filter pump motor's manual reset
protection device.
The filter envelope should be changed after 10-12 filterings or
whenever it becomes clogged with crumbs. Proceed as follows:
The filter union could be hot. Wear protective glove or
cloth, or severe burns could result.
Use care to prevent burns caused by splashing of hot
shortening.
1.
Move the main POWER switch to the OFF position.
2.
Disconnect the filter union and remove the filter drain
pan from beneath the frypot.
3.
Remove the filter screen assembly from the drain pan.
4.
Wipe the shortening and crumbs from the filter drain pan.
Clean the drain pan with soap and water. Thoroughly rinse
with hot water.
5.
Unthread the standpipe from the filter screen assembly.
6. Remove the crumb catcher and clean with soap and water.
Rinse thoroughly with hot water.
7.
Remove the filter clips and discard the filter envelope.
8.
Clean the top and bottom filter screen with soap and water.
Rinse thoroughly with hot water.
OFE14X
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ofe-142

Table of Contents