C1500 SPECIAL
PROGRAMMING
Special Programming is used to set the items below:
 Fahrenheit or Celsius
 Initialize System
 Lock or Unlock Controls
 Fryer Type – Open or Pressure
 Heat Source – Electric; Gas w/standing pilot;
Gas w/electronic ignition; Gas-Induced Draft
 Vat Type - Split or Full Vat (frypot)
 Oil Type - Solid or Liquid
1.
To enter Special Programming, turn off power switch
(either side). Press and hold
switch back on.
2.
"SPEC" "PROG" followed by, "DEG" "°F" or "°C". Use
to choose "°F" or "°C".
3.
Press
and "INIT" shows in the display.
Press and hold the right
"In-2", "In-1" followed by "Init Sys" "DONE DONE". The
controls now are reset to factory parameters, the time set to
0:00 and temperature 190°F or 88°C.
4.
Press
and "LOCK" or "UNLOCK" shows in the
displays. Use
"UNLOCK".
5.
Press
and "FRYR" shows in left display and the right
display should show "OPEN". Use
from "OPEN" to "PRES" if needed.
6.
Press
and "HEAT" shows in the left display and the
type of heat shows in the right display. Use
to change the heat type: "ELEC" for electric models; "GAS"
for units with standing pilot; "SSI" for units with solid state
ignition; "IDG" for units with induced draft gas burners.
7.
Press
and "VAT" shows in the left display and the
type of vat shows in the right display . Use
choose "SPLIT" or FULL" vat (frypot) type.
8.
Press
and "MELT" shows in the left display and
Solid" or "LIQD" shows in the right display. Use
to choose "Solid", if using solid shortening,
or "LIQD", if using liquid shortening.
9.
Press and hold
time.
and turn the power
and display shows "In-3",
to choose "LOCK" or
to exit Special Programming at any
OFE14X
to change
to