5.4

Detecting and correction of the umbalance

5.4.1
After setting wheel dimensions, press <START> to spin the wheel and start the measurement run.
5.4.2
At the end of the spin the wheel will brake automatically and the display will show the weight position and weight
requirement to correct the wheel's umbalance.
5.4.3
If umbalance shown is 0, press <FINE> to show residual umbalance.
F
. 32: inside weight indication
IG
NOTE:
OPT light blinking after the measurement indicates that static umbalance is exceeding more than 20grs.
Optimization procedure is suggested.