23 January 2020 WARNING .This document contains information which is the property of FASEP 2000 srl and all rights are reserved. This manual shall not be photocopied or reproduced in any way without the prior written consent of FASEP 2000 srl.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 ORIGINAL INSTRUCTIONS TABLE OF CONTENTS WARNING ................... ii SYMBOLS AND CONVENTIONS .
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 PRESENTATION Intended Use This unit is designed to measure and correct static and dynamic unbalance of vehicle wheel, the dimension and weight of which are within the working range of the machine (see “Technical Data”appendix for reference) This unit is meant for a professional use.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 INSTALLATION Moving the unit WARNING When the unit has to be moved: never lift balancer by motor shaft or by neighborhood of it. Assembling the unit For ease of transportation, the wheel balancer might be disassembled into units. If necessary, assembling instruction are provided within each package.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 USE THE CONTROL PANEL . 8: Panel Balatron 2000 Meaning of keys at the keyboard These instructions apply to Normal Operating Mode. Other function maybe activated by these keys in other operating modes (see Special Functions).
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 CALIBRATION How to calibrate the Wheel Balancer (USER) NOTE the following symptoms indicate need for calibration: a) check calibration program fails. b) constant low or high weight readings.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 How to check the calibration of Wheel Balancer (USER) ATTENTION select mode CAL USR Press <+/-> to select CAL TEST . 14 Place a wheel on the flange ( Fig. 13).
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 ALU-SE Calibration (USER) Switch on the wheel balancer. Press <SET> when SOF X.XX (software version) is displayed. ATTENTION select mode CAL USR . 18 Put the rod in 0 position (Fig. 17) .
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 MEASUREMENT AND CORRECTION OF UNBALANCE Placing the wheel rim on the wheel balancer 5.1.1 Select the cone or flange suitable for the wheel to be balanced. Specific mounting instructions are delivered with each flange.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 Input of Rim Dimensions NOTE DOUBLE OPERATOR option (optional for B212): this wheel balancer can be used by 2 operators in the same time. Everyone can memorizes the dimensions of the wheel to balance with 9 <OPER> button. The machine memorizes the operating procedure too.
Page 13
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 5.3.3 ALU S-1 MODE / ALU S-2 MODE ( Manual input) Press MODE to select the operating mode. ( Fig. 23, Fig. 24 ). Select the wheel diameter.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 Detecting and correcting unbalance 5.4.1 After setting wheel dimensions, press <START> or close the safety cover (optional) to spin the wheel and start the measurement run. CAUTION Wheel start automatically when safety cover is closed.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 HOW TO OPTIMIZE UNBALANCE OF THE WHEEL Measure the unbalance of the rim only. Once the measurement of rim unbalance is calculated, press 11<FUNC> to enter optimization function.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 HOW TO USE SPLIT WEIGHT FUNCTION Measure the unbalance of the wheel. Once the measurement of unbalance is calculated, press 11<FUNC> to enter split function. Turn the wheel until POS 1 is displayed.
Fasep 2000 srl Rev. 1.8 Balatron 222/212: User’s Manual 23 January 2020 SPECIAL FUNCTIONS MENU Enter in the special functions menu Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Calibration of wheel balancer CAL tSt Control of the calibration of electronic sensors...
WARNING FASEP 2000 srl shall not be responsible for any inconvenience, breakdown, accidents caused directly or indirectly by unauthorized service. Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit.
[when servicing the unit] Make sure power sources are disconnected before service on the unit is performed. Service to PCB, electrical and mechanical parts should be done only by an Authorized FASEP 2000 Service Center. Errors and Malfunctions recognized by the Computer Errors may apply to some model only.
Page 21
BS EN 60204-1:2018 BS EN IEC 61000-6-3:2021 BS EN IEC 61000-6-1:2019, BS ISO/IEC 17050-1:2010 Ronta, Firenze Data_____________ FASEP 2000 srl Fulvio Boni,Presidente Persona autorizzata a costituire il Fascicolo Tecnico: Fasep 2000 srl, Via Faentina 96 - Ronta, 50032 Borgo San Lorenzo (Fi)
Page 22
UNI EN ISO 12100:2010, EN 60204-1:2018, BS EN IEC 61000-6-3:2021, BS EN IEC 61000-6-1:2019, ISO/IEC 17050-1:2010 Ronta, Firenze Data_____________ FASEP 2000 srl Fulvio Boni,Presidente Persona autorizzata a costituire il Fascicolo Tecnico: Podmiot odpowiedzialny za dostarczenie dokumentacji techniczenej: Fasep 2000 srl, Via Faentina 96 - Ronta, 50032 Borgo San Lorenzo (Fi)
Need help?
Do you have a question about the B222 and is the answer not in the manual?
Questions and answers