ProBio (QR)
Function Description
Function Name
Door Lock Delay (s)
Door Sensor Delay
(s)
Door Sensor Type
Verification Mode
Door available time
period
Normal open time
Period
Master Device
Auxiliary input
configuration
Verify mode by
RS485
Speaker Alarm
Reset Access Setting
P a g e
| 48
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1 to 10 seconds; 0 seconds represents disabling the function.
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
There are three Sensor types: None, Normal Open, and Normal Closed.
None: It means the door sensor is not in use.
Normally Open: It means the door is always left open when electric power is on.
Normally Closed: It means the door is always left closed when electric power is on.
The supported verification mode includes Password/Card/Face, User ID only,
Password, Card only, Password + Card, Password/Card, Face only, Face +
Password, and Face+Card.
It sets the timing for the door so that the door is accessible only during that
period.
It is the scheduled time-period for "Normal Open" mode so that the door is
always open during this period.
While configuring the master and slave devices, you may set the state of the
master as Out or In.
Out: A record of verification on the master device is a check-out record.
In: A record of verification on the master device is a check-in record.
Sets the door unlock time period and auxiliary output type of the auxiliary
terminal device. Auxiliary output types include None, Trigger door open,
Trigger Alarm, Trigger door open and Alarm.
It is the verification mode used by the device when it is the master unit. This
option will be displayed only if RS485 reader function is enabled.
It transmits a sound alarm or disassembly alarm from the local. When the door
is closed or the verification is successful, the system cancels the alarm from the
local.
The access control reset parameters include door lock delay, door sensor delay,
door sensor type, verification mode, door available time period, normal open
time period, master device, and alarm. However, erased access control data in
Data Mgt. is excluded.