3 Installation

Location of the Storage Tank

The storage tanks can be installed in any room pro-
tected against a temperature drop below 0°C, which
will prevent freezing of water in the tanks. It should
be installed in a convenient place for the user (eg
basement, boiler room, etc.), in a way that will enable
easy maintenance or servicing in the future. Consider
the fi lled tank weight when selecting its location. As a
rule, select the device location in a way allowing the
rational routing of both the hot water and the heating
lines. To avoid loss of heat energy, all hydraulic pipes
should be thoroughly insulated.
INFORMATION
When installing the storage tank, consider
free space above the unit required to main-
tain/replace the protective magnesium anode.
If space for the installation of the magnesium bar an-
ode (used as standard), you can use the appropriate
titanium anode (that should be installed in accordance
with the anode manufacturer's instructions) or the ap-
propriate magnesium chain anode. For the specifi ca-
tion of the protective anodes available at NIBE, see
Section 6 "Accessories and Spare Parts".
Fig. 6 Min clearance for the replacement of the pro-
tective magnesium anode.
CAUTION
For the minimum clearances to be observed
when installing the storage tank, see Table 3.
BA-ST 9022-9100-FE
A
min
INFORMATION
You can decrease the A
ing the magnesium chain anode or titanium
anode.
Fig. 7 Levelling the unit.
The storage tank stands on three feet that can be ad-
justed within the range from 0 to 15 mm to level the
tank.

Housing Disassembly

Removable housing with thermal insulation facilitates
transport and installation of the storage tank. Disas-
sembly the housing in the following order (see Fig. 8):
1. Remove the Temperature gauge, plug of the
heating element connector pipe and blanking
plate of the inspection opening.
2. Remove the upper cover of the housing together
with thermal insulation.
3. Remove the plugs from the connector pipes and
black bushings.
4. Remove the fi xing screws and the strip connect-
ing the housing jacket.
5. Remove the jacket surrounding the tank (housing
jacket.)
6. Remove the four-piece thermal insulation.
After the installation of the storage tank in its fi nal lo-
cation, reinstall the removed components in the re-
verse order.
clearance when us-
min
0-15 mm
Chapter 3 |
Installation
7