Maintenance and care
VACUUM/PETROL ENGINE
●
Only persons with the appropriate knowledge and
ability are allowed to repair the device
Service interval
daily
After one week
After one month
Minimum 1x per year
(at rough conditions shorten the
interval)
Fig. 1
●
Disassemble filter cap.
●
ELECTRICS
Service interval
After 25 operating hours
All 50 operating hours
●
Check engine oil level (see Honda operating instructions)
●
Clean air filter and blower (see fig. 1-3).
●
Control and tighten all screws and connection
●
Grease all joints, bolts, guidance's.
●
Grease all grease nipple every month
●
Oil change according to manufacturer data (HONDA) replacement
(note the specifications).
●
Check of all the suspension parts, bolts and straps. Check for
corrosion and safety by an expert. (=> BGR 500)
●
Fig.2
●
Check seal and renew when
damaged.
Maintenance work
Control all electrical connections and/or retighten (the implementation is only
allowed by an expert)
●
Check all fuses (if existing).
●
Check the electric cabeling for breaks and abrasion (if necessary replace it
(only qualified personal)).
●
Before the device is used again, it has to be checked
by an expert.
Maintenance work
●
Remove Filter and clean
(compressed air), when necessary
renew
●
ATTENTION!
Clean filter daily with
compressed air. Do not hit filter
cartridge against any object!!!
Exchange in case of much dirt.
35 / 38