Section 5 • Maintenance/Service
3. In most cases there will be foam in the oil, so you
must fill the bottle up to the top and then wait for
the foam to dissipate. Repeat this step as many times
as necessary (around 4 to 6 times) until the clear oil
level reaches ¾ full, see sequence in Figure 5-6.
4. After all the foam dissipates, tighten the sample
bottle cap.
5. Tighten the oil sampling valve cap.
6. For valve #3709A only: back seat the knurled lock-
nut by turning it counter-clockwise. This is to pre-
vent any accidental release, see Figure 5-4 (c).
7. Attach the filled sampling information label to the
bottle and mail the sample out to the oil analysis lab
immediately.
Missing information from the sampling label may result
in longer turnaround time as the laboratory will need to
request the info before the sample can be tested.
5 – 10
NOTE
Figure 5-6. Stages of the Oil Sample Taking Process
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD

Oil Sample Analysis Report

A copy of the oil analysis report is also sent to Vilter. See
Appendices for a sample of the oil analysis report.
An oil analysis report will show the physical properties of
the oil, such as:
Water content
Viscosity
Acid number
Particle count
Antioxidant level
Wear metals
Contaminating/additive metals
NOTE