Unit Initial Oil Charging; Priming Oil Lines And Compressor - Emerson Vilter VSS Installation, Operation & Maintenance Manual

Compressor unit
Hide thumbs Also See for Vilter VSS:
Table of Contents

Advertisement

Section 3 • Installation

Unit Initial Oil Charging

(Reference Figure 3-17)
10. At initial start up, compressor unit must be off and
depressurized prior to initial oil charging.
11. Using a properly selected oil pump, connect oil
pump to oil separator drain valve (10) (for oil sepa-
rator drain valve location, see Figure 3-16).
12. Open oil separator drain valve (10) and fill oil separa-
tor (1) to Maximum NON-Operating Level.
13. Once Maximum NON-Operating Level has been
reached, shut off oil pump, close oil separator drain
valve (10) and remove oil pump.
14. If equipped with remote oil cooler, refer to Priming
Compressor Units Equipped with Remote Oil Cooler
procedure (see Appendix G).
R717 VAPOR
TO ATMOSPHERE
1
10
DRAIN
PI
PT
001
001
BLEED
LOW PRESSURE
R717 VAPOR INLET
SUCTION
STOP VALVE
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Figure 3-16. Oil Drain Valve
250#
PI
PT
002
002
BLEED
V100
OIL SEPARATOR
LG
001
LG
002
TW
TW
TW
TW
750W
750W
750W
QE
QE
QE
TE
001
002
003
005
TE
TW
004
SUCTION
CHECK VALVE
FG
001
TE
TW
001
9
OIL CHARGE
8
D100
MOTOR
C100
D102
COMPRESSOR
CAPACITY
Figure 3-17. Priming Oil Lines and Compressor

Priming Oil Lines and Compressor

Continue with the following steps to prime the oil lines
and compressor:
15. Make sure valves on oil circuit are in the open posi-
tion. In this case, make sure valves (2), (3), (5), (6)
and (7) are in the open position.
16. Energize compressor unit. Vission 20/20 will ener-
gize oil heaters.
17. Run oil pump (4) for 15 seconds only.
18. Wait minimum of 30 minutes to allow oil to drain
from compressor (8).
19. If compressor unit is not being started right away,
repeat steps 6 to 9 prior to starting.
Oil Drain Valve
(Oil Separator)
DISCHARGE CHECK VALVE
DISCHARGE STOP VALVE
100
PSID
OPTIONAL
MW
(STANDARD FOR BOOSTER &
SWING COMPRESSORS ONLY)
MOTOR AND
OIL PUMP
4
P100
2
5
3
PT
003
PI
BLEED
003
7
DRAIN
PT
004
D103
PI
VOLUME
BLEED
004
HIGH PRESSURE
R717 VAPOR OUTLET
TE
TW
002
R717 LIQUID/VAPOR
T
E100
R717 LIQUID
6
OUTLET
INLET
3 – 21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vilter vsmVilter vshVilter vssh

Table of Contents