Section 5 • Maintenance/Service

Compressor Shaft Seal Replacement

Shaft Seal Assembly

The shaft seal is made up of a mating ring and a carbon
or silicon carbide (SC) component.
The mating ring is the rotating part of the seal and is in-
stalled against the shaft shoulder. It has a drive notch on
one end which aligns with the drive pin inserted in the
shaft.

Handling Seal Face with Care

Avoid touching seal faces as much as
possible during installation.
Be sure to always keep seal faces
face-up, rather than face-down, see
image on the right.
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Figure 5-58. Shaft Seal Assembly
Figure 5-59. Handling Seal Face with Care
Carbon or SC component is the stationary part of the
seal and is installed into the shaft seal housing using an
O-ring.
The shaft seal housing with the stationary part is assem-
bled in the compressor main housing using an O-ring,
see Figure 5-58.
The shaft seal needs to be carefully handled and
installed to function properly. Please see Figure 5-59 for
details.