Maximum Fluid Working Pressure
Fluid:Oil Pressure Ratio
Fluid Inlets
Fluid Outlets
Fluid Circulation Ports
Maximum Fluid Temperature
Maximum Output (10 weight oil at
ambient temperature)
Output per Cycle (A and B)
Line Voltage Requirement
Amperage Requirement
Heater Power
(A and B heaters total, no hose)
Hydraulic reservoir capacity
Recommended hydraulic fluid
Sound power, per ISO 9614-2
Sound pressure, 1 m from equipment
Weight
Wetted Parts
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
34
Data
Models IPH-25 and IPH-40: 2000 psi (13.8 MPa, 138 bar)
Model IPH-25: 1.91:1
Model IPH-40: 1.64:1
Component A (ISO): 1/2 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum
Component B (RES): 3/4 npt(f), 250 psi (1.75 MPa, 17.5 bar) maximum
Component A (ISO): #8 JIC (3/4-16 unf), with #5 JIC adapter
Component B (RES): #10 JIC (7/8-14 unf), with #6 JIC adapter
1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum
190°F (88°C)
Model IPH-25: 22 lb/min (10 kg/min) (60 Hz)
Model IPH-40: 50 lb/min (23 kg/min) (60 Hz)
Model IPH-25: 0.063 gal. (0.23 liter)
Model IPH-40: 0.076 gal. (0.29 liter)
230V 1 phase and 230V 3 phase units: 195-264 Vac, 50/60 Hz
400V 3 phase units: 338-457 Vac, 50/60 Hz
See Models, page 2.
See Models, page 2.
3.5 gal. (13.6 liters)
Citgo A/W Hydraulic Oil, ISO Grade 46
90.2 dB(A)
82.6 dB(A)
All IPH-25 Models: 535 lb (243 kg)
IPH-40 Models with 12.0 kW Heaters: 597 lb (271 kg)
IPH-40 Models with 15.3 kW Heaters: 597 lb (271 kg)
Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings