Operation - Graco IPH-25 Series Installation & Operation Manual

Shot controller
Table of Contents

Advertisement

Operation

The AR Pour Gun and shot controller modify the
hydraulic proportioner to pour instead of spray but
all operation procedures from hydraulic proportioner
operation manual 312062 are applicable.
Startup
See hydraulic proportioner operation manual 312062.
Change Operating Mode
Operating modes Shot ("Sh") and Manual ("Mn") will
always be available and Sequence mode ("Sq-X") will be
available when one or more sequences are created by
the user. See Setup Screen #3: Shot Sequences on
page 19. To change the operating mode, hit the Mode
Select key on the HMI until the desired operating mode
is shown in the top left corner of the screen. Hit the top
soft key to confirm the mode selection.
Change Shot Number
Only shots with non-zero volumes/weights can be
selected.
To change the selected shot from the idle run screen, hit
the up or down arrow keys. When the desired shot is
selected, hit the top soft key to confirm the selection.
F
. 16: Run Screen Shot Editing, Changing Operating Mode
IG
1
1
2
1
When changing the operating mode or shot number, the item being changed
will be highlighted
2
During Run Screen Shot Editing, the shot quantity will be highlighted
3
A password may be required to edit this item
4
All changes must be confirmed or cancelled
Change Shot Volume/Weight
To change the defined shot volume or weight for the
selected shot, first enter Run Screen Shot Editing mode
by pressing and holding both the up and down arrow
keys for three seconds. Use the up and down arrow keys
to change the shot volume/weight then confirm the
change when prompted.
If Run Screen Shot Editing is disabled, navigate to setup
screen #2. Select the desired shot and use the up and
down arrow keys change the shot volume/weight and
confirm the change when prompted. See Setup Screen
#2: Shot Number Definitions on page 19.
Sequence Mode Options
Restart Shot Sequence
In sequence mode, to restart a shot sequence from the
first defined shot, press and hold the down arrow key for
three seconds. When prompted, hit the top soft key to
confirm restarting the sequence.
Repeat/Skip Shot in Sequence
To repeat a shot, while at the idle run screen press the
down arrow key and confirm when prompted. To skip a
shot, while at the idle run screen press the up arrow key
and confirm when prompted.
2