DRAINING THE LIQUID
- Remove the cover plate 1.
- Remove the filler plug 2 to ensure that the oil is drained properly.
- Open valve 3 to ensure that the oil is drained properly.
- Place a container under the hose 4.
- Undo the clamp 5 and remove the hose.
- Let the cooling circuit drain entirely while ensuring that the ports do not get clogged.
- Check the condition of the hoses and their attachments, and change if necessary.
- Rinse the circuit with clean water, or use a cleaning agent if necessary.
FILLING WITH COOLING LIQUID
- Refit the hose 4 with the clamp 5.
- Close up valve 3.
- Slowly fill the system with the coolant (
filler port 6.
- Refit the filler plug 2.
- Run the engine at idle for a few minutes.
- Visually check that there is no leakage in the radiator and pipes.
- Check the level and refill if necessary.
CHECK
CHECK
CHECK
CHECK
CHECK
CHECK
CHECK
CHECK
LUBRICANTS AND FUEL) through the
Water pump and thermostat *
Hydrostatic transmission circuit pressures *
Hydrostatic transmission control flow *
Hydrostatic transmission / accelerator cut-off operation *
Injection pump *
Injectors *
Radiator *
Alternator and starter *
3 - 29