Replace The Compressor - VERDER VERDERAIR VA-EH50 Repair Parts

Electric-operated diaphragm pumps
Hide thumbs Also See for VERDERAIR VA-EH50:
Table of Contents

Advertisement

Repair
Replace the
the Compressor
Compressor
Replace
Replace
the
Compressor
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
1. Follow the
Pressure Relief Procedure, page
2. Remove electrical power from the pump.
3. Remove the 8 bolts holding the pump to the
mounting surface.
4. Tip the pump on its side to provide access to the
compressor box.
5. Remove riser bracket (35).
6. Remove the air line (A1) from the compressor.
Disconnect the compressor wires at the terminal
block (L1, L2, and ground). Remove the four
bolts, and carefully pull the compressor out of
the box.
7. Use the four bolts to install the new compressor.
Connect the air line from A1 to A1, as shown.
8. Connect the wires from the new compressor to
the terminal block, as shown.
9. Replace riser bracket.
10. Return the pump to its mounting location. Secure
it with the 8 bolts.
11. Return power to the pump.
26
13.
A
L2
L1
859.0773