VERDER VERDERAIR VA-EH50 Repair Parts page 23

Electric-operated diaphragm pumps
Hide thumbs Also See for VERDERAIR VA-EH50:
Table of Contents

Advertisement

Disconnect
Disconnect the
Disconnect
the
the Motor
Motor
Motor and
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
NOTE:
NOTE: Normally, the motor remains connected to the
NOTE:
gearbox. Disconnect the motor only if you suspect
that the motor or gearbox must be replaced.
TIP:
TIP: Clamp the gearbox bracket (15) to the bench.
TIP:
Start at step 1 for ATEX or Flameproof motors.
Standard AC motors (AC, A1, or A2) are of one piece
859.0773
and Gearbox
and
Gearbox
Gearbox
with the gearbox, so begin with step 3.
NOTE: Use a hoist and sling to remove motor weight
NOTE:
NOTE:
from the gearbox during removal.
1. Turn off the pump and disconnect power.
2. Use a 3/4 in. socket wrench to remove 4 screws
(122).
3. Pull the motor (121) straight off of the gearbox
(118).
4. Use a 3/4 in. socket wrench to remove 4 bolts
(17) and nuts (18, if present). Lift the gear box off
of the bracket.
NOTE:
NOTE: If you have an AC motor with gearbox, lift
NOTE:
the whole unit off of the bracket.
Repair
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Verderair va-e2h52Verderair va-e2h53Verderair va-e2h54Verderair va-e2h54 sfVerderair va-e2h52 3aVerderair va-e2h52 sb

Table of Contents