Download Print this page

Cleaning The Flue; Malfunctions - RAIS Nexo 100 User Manual

Hide thumbs Also See for Nexo 100:

Advertisement

English

Cleaning the flue

To access the flue, remove the vermiculite smoke deflector plate by removing the two
locking pins and pulling the plate forwards so it can be lifted out.
Remove the smoke detector plate by tilting it backwards and turning it at a slight angle.
Carefully lift it out.
Then remove the baffle by lifting it and pulling it forwards.
Lift out the baffle.
Remove any dirt and dust and replace in the reverse order.
NOTE!
Take care when positioning the smoke deflector plate and baffle.

Malfunctions

Smoke leakage around the door
This may be due to insufficient draught in the chimney <12 Pa
• check whether the flue or chimney are clogged up
• check whether the extractor hood is switched on, in which case, switch off the
extractor hood and open a window/door close to the stove for a short period.
Soot on the glass
Possible causes
• the fuel is too wet
• the damper adjustment is too low
Ensure the stove is heated up properly during lighting, before the door is closed.