Thank you for purchasing a RAIS wood burning stove. These appliances have been ap- proved by HETAS Ltd as intermittent operating appliances for burning wood logs only. A RAIS wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home.
The heated air pours out at the top of the stove, which ensures a circulation of warm air throughout the room. The stoves are equipped with a “cold” lever – RAIS special feature – which means you could almost do away with gloves. Be aware, however, that all exterior surfaces become...
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Installation instructions The following pages give instructions for the safe and proper installation of this heating ap- pliance in the UK. These instructions cover the basic principles of installation, although detail may need slight modification to suit particular local site conditions.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Chimney The chimney is the driving force which makes the stove function. In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 Pa so as to clear the products of combustion and prevent problems of smoke emanating into the room when firing.
Page 9
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper...
Page 10
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Rondo Manufacturer’s Plate Producent RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark EN 13240:2001+A2:2004 EC.nr. 407 Anordning til træ RONDO 92 Afstand til brændbart, bagvæg 150 mm Afstand til brændbart, sidevæg 350 mm Afstand til brændbart, møblering...
When you choose where to set up your RAIS wood burning stove, you should consider the heat distribution to the other rooms. This will enable you to get the best use out of your stove.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Adjustment of chimney connection The stove is always delivered for top connection, but can be changed to rear connection as follows: Remove baffle plate and smoke diverter (see clean- ing and care).
Page 13
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Remove the casing knock-out. Remove protective cover and seal and place over the hole on the top - make sure that the seal is positioned properly. Tighten the assembly using the 3 M6 nuts.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Installation distance in case of combustible wall To find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Normal set-up (right-angled) secure base RONDO 92 RONDO 120 A. Distance to furniture 1050 mm 1050 mm Distance to flammable materials: B. - in front (floor) 300 mm 300 mm C.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 360° swivel base - normally placed as a room divider RONDO 120 Distance to furniture 1050 mm Distance to flammable materials: - in front (floor) 300 mm Distance to firewall...
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 For the Installer Finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Operating instructions Please note that HETAS Ltd Appliance Approval only covers the use of dry seasoned wood logs on this appliance. HETAS Ltd Approval does not cover the use of other fuels either alone or mixed with the wood logs, nor does it cover instructions for the use of other fuels.
2-3 days before you need it. Regulating the combustion air All RAIS stoves are equipped with a one-handed operating lever for regulating the damp- er. The stove-specific regulating mechanisms can be seen on the diagrams. Primary air is the combustion air added to the primary combustion zone, i.e. the bed of glowing embers.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Using the wood burning stove Adjustment of air damper The damper has 3 settings Position 1 The air damper is closed, which means no air supply. Position 2 Push the lever to the right until it stops. This position gives full secondary air.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 First usage A careful start pays off. Start with a small fire, so that the wood burning stove can get accus- tomed to the high temperature. This gives the best start and any damage is avoided.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Lighting and fuelling To light the stove, use alcohol briquettes or similar, as well as approx. 2 kg of firewood, split into kindling sticks. Set the air damper to the fully open position.
Page 23
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 When the flames are clear - after approx. 5-10 min. - close the door. Damper - see adjustment of air damper. After approx. 10-20 min. - when you have a good bed of glowing embers - add 2-3 pieces of wood.
- Moisten a piece of paper or newspaper, dip it in the ash, and rub the sooty glass with - Now rub with a piece of paper and the glass will become clean. - As an alternative you can use glass polish, which you can buy from you RAIS distributor. Clean the exterior with a dry sponge.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Cleaning of the flue ways Remove the baffle plate by pivoting it Next, remove the flue diverter by lifting it up up at one end and tilting it slightly at an and pulling it forward.
- leaky chimney - leakage between chimney and flue If your stove continues to malfunction, we recommend that you contact your RAIS distribu- tor or chimney sweep. IMPORTANT!! To ensure safe burning there must be clear yellow flames or clear embers at all times.
RAIS - Manual for RONDO 92 & RONDO 120 Accessories and spare parts If spare parts other than those recommended by RAIS are used, the warranty is voided. All replaceable parts can be bought as spare parts from your RAIS distributor.
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Spare parts diagram - RAIS Rondo 92 Number Item no. / description 505700170 Soapstone top plate without hole 505700270 Soapstone top plate with hole 505060190 Top plate without hole 505060290...
Page 29
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120...
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120 Spare parts diagram - RAIS Rondo 120 Number Item no. / description 505700170 Soapstone top plate without hole 505700270 Soapstone top plate with hole 505060190 Top plate without hole 505060290...
Page 31
ENGLISH RAIS - Manual for RONDO 92 & RONDO 120...
Page 32
RAIS A/S Industrivej 20 DK-9900 Frederikshavn www.rais.dk...