Power-Saving Mode (Standby); Special Parameters (Advanced Settings) - EWM LP-XQ Operating Instructions Manual

Table of Contents

Advertisement

Functional characteristics

Power-saving mode (Standby)

1 Preparation
Switch off the welding machine.
Unscrew the gas nozzle from the welding torch.
Trim the welding wire so that it is flush with the contact tip.
Retract the welding wire a little (approx. 50 mm) on the wire feeder. There should now be no more
welding wire in the contact tip.
2 Configuration
Press and hold "Welding power rotary knob", at the same time switch on the welding machine (at least
2 s). Release rotary knob (device changes after a further 5 s to the first parameter cable resistance 1).
Turn the "Welding power rotary knob" to select the appropriate parameter. Parameter rL1 must be ad-
justed for all machine combinations. In case of welding systems with a second power circuit – if two
wire feeders are to be operated from a single power source, for example – a second adjustment with
parameter rL2 must be performed.
3 Alignment/Measurement
Applying slight pressure, put the welding torch in place with the contact tip on a clean, purged location
on the workpiece and then press the torch trigger for approx. 2 seconds. A short-circuit current will
flow briefly, which is used to determine and display the cable resistance. The value can be between
0 mΩ and 40 mΩ. The new value is immediately saved without requiring further confirmation. If no va-
lue is shown on the right-hand display, then measurement failed. The measurement must be repeated.
4 Restoring welding standby mode
Switch off the welding machine.
Screw the gas nozzle onto the welding torch.
Switch on the welding machine.
Insert the welding wire.
5.9
Power-saving mode (Standby)
You can activate the power-saving mode by setting a parameter in the machine configuration menu (time-
controlled power-saving mode
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the ma-
chine is ready for welding again.
5.10

Special parameters (advanced settings)

Special parameters (P1 to Pn) are applied for customer-specific configuration of machine functions. This
allows the user maximum flexibility in optimising their requirements.
These settings are not configured directly on the machine control since a regular setting of the parame-
ters is generally not required. The number of selectable special parameters can deviate between the ma-
chine controls used in the welding system (also see the relevant standard operating instructions).
If required, the special parameters can be reset to the factory settings > see 5.10.2 chapter.
54
) > see 5.8 chapter.
099-5TLPXQ-EW501
29.01.2021