5.10.1 Selecting, Changing And Saving Parameters - EWM LP-XQ Operating Instructions Manual

Table of Contents

Advertisement

5.10.1 Selecting, changing and saving parameters

Display
099-5TLPXQ-EW501
29.01.2021
B
A
B
Setting/selection
Wire inching / wire return ramp time
0 = ------- normal inching (10 s ramp time)
1 = ------- fast inching (3 s ramp time) (ex works)
Block program "0"
0 = ------- P0 enabled
1 = ------- P0 blocked (Ex works)
Display mode for Up/Down welding torch with one-digit 7-segment display (two
keys)
0 = ------- normal display (ex works) program number/welding power (0–9)
1 = ------- display toggles between program number/welding type
Program limitation
Programs 1 to max. 15
Ex works: 15
Special cycle in the special latched and non-latched operating modes
0 = ------- normal (previous) non-latched/latched (Ex works)
1 = ------- WF3 cycle for non-latched/latched
Functional characteristics
Special parameters (advanced settings)
+
Figure 5-45
A
B
55

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LP-XQ and is the answer not in the manual?

This manual is also suitable for:

M3.7x-n

Table of Contents