Pentair EVERPURE H Series Installation And Operation Manual page 13

Hide thumbs Also See for EVERPURE H Series:
Table of Contents

Advertisement

Available languages

Available languages

EVERPURE
H-300-NXT Cartridge - Part Nos. EV927441, EV927446
IMPORTANT NOTICE: Read this Everpure* Performance Data Sheet
and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
• Finely polishes treated water to premium quality for drinking and cooking.
• Reduces chlorine taste and odor.
• Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and sulfides - As tested by Pentair.
• NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium
and Giardia by mechanical means.
• Controls even extreme levels of common "off" tastes and odors, including
those which are earthy, moldy and fishy.
• Reduces lead.
• Effectively reduces Volatile Organic Chemicals (VOCs).
• Reduces particles as small as 0.5 micron in size by mechanical means.
• NSF/ANSI Standard 401 certified for the reduction of the incidental
contaminants/emerging compounds listed in the performance data sheet.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI
This system has been tested according to NSF/ANSI 42, 53 and 401
for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42, 53 and 401.
Influent
Substance
Challenge
Permissible Product
Concentration
Water Concentration
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulate, Class I
at least 10,000
particles 0.5 to <1 µm
particles/mL
Standard 53—Health Effects
Cyst
Minimum 50,000/L
Lead 6.5
0.15 mg/L ± 10%
0.010 mg/L
Lead 8.5
0.15 mg/L ± 10%
0.010 mg/L
Chloroform
0.300 mg/L
0.015 mg/L
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
Standard 401—Emerging Contaminants
Phenytoin
200 ± 20% ng/L
0.000030 mg/L
Ibuprofen
400 ± 20% ng/L
0.000060 mg/L
Naproxen
140 ± 20% ng/L
0.000020 mg/L
Estrone
140 ± 20% ng/L
0.000020 mg/L
Bisphenol A (BPA)
2,000 ± 20% ng/L
0.000300 mg/L
Nonylphenol
1,400 ± 20% ng/L
0.000200 mg/L
NSF/ANSI Standard 401 have been deemed as "incidental contaminants/emerging compounds".
Incidental contaminants are those compounds that have been detected in drinking water supplies at
trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/
perception of drinking water quality.
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
Max.
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥ 50%
86.8%
≥ 85%
98.8%
99.95%
99.99%
99.99%
99.3%
>99.3%
98.7%
99.3%
95.8%
98.9%
>96.3%
>95.8%
>96.8%
>97.2%
>99.2%
>97.1%
PERFORMANCE DATA SHEET
H-300-NXT DRINKING WATER SYSTEM
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,136L)
• Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Influent Challenge
Substance
Concentration mg/L
alachlor
0.050
atrazine
0.100
benzene
0.081
carbofuran
0.190
carbon tetrachloride
0.078
chlorobenzene
0.077
chloropicrin
0.015
2,4-D
0.110
dibromochloropropane (DBCP)
0.052
o-dichlorobenzene
0.080
p-dichlorobenzene
0.040
1,2-dichloroethane
0.088
1,1-dichloroethylene
0.083
cis-1,2-dichloroethylene
0.170
trans-1,2-dichloroethylene
0.086
1,2-dichloropropane
0.080
cis-1,3-dichloropropylene
0.079
dinoseb
0.170
endrin
0.053
ethylbenzene
0.088
ethylene dibromide (EDB)
0.044
haloacetonitriles (HAN):
bromochloroacentonitrile
0.022
dibromoacetonitrile
0.024
dichloroacetonitrile
0.0096
trichloroacetonitrile
0.015
haloketones (HK):
1,1-dichloro-2-propanone
0.0072
1,1,1-trichloro-2-propanone
0.0082
heptachlor
0.080
heptachlor epoxide
0.0107
hexachlorobutadiene
0.044
hexachlorocyclopentadiene
0.060
lindane
0.055
methoxychlor
0.050
pentachlorophenol
0.096
simazine
0.120
styrene
0.150
1,1,2,2-tetrachloroethane
0.081
tetrachloroethylene
0.081
toluene
0.078
2,4,5-TP(silvex)
0.270
tribromoacetic acid
0.042
1,2,4-trichlorobenzene
0.160
1,1,1-trichloroethane
0.084
1,1,2-trichloroethane
0.150
trichloroethylene
0.180
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
0.300
bromodichloromethane
chlorodibromomethane
xylenes (total)
0.070
The H-300-NXT is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI
42, 53, and 401 for the claims specified on the
Performance Data Sheet.
C
US
EPA Est. 002623-IL-002
EVERPURE
Maximum permissible Product
Water Concentration mg/L
0.001
0.003
0.001
0.001
0.0018
0.001
0.0002
0.0017
0.00002
0.001
0.001
0.0048
0.001
0.0005
0.001
0.001
0.001
0.0002
0.00059
0.001
0.00002
0.0005
0.0006
0.0002
0.0003
0.0001
0.0003
0.0004
0.0002
0.001
0.000002
0.00001
0.0001
0.001
0.004
0.0005
0.001
0.001
0.001
0.0016
0.001
0.0005
0.0046
0.0005
0.001
0.015
0.001
H-Series Water Filtration Systems
• 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents