DMX Control Wiring and Termination

DMX wire preparation will vary with the type of wire and termination kit being utilized. Please refer to
the instructions provided with the DMX termination kit for specifics on the wire preparation. DMX
termination is made to J8 and J9 on the termination board.
From DMX
source
After completing the DMX data connections, you must properly terminate the DMX line using the
termination switch (S2) on the panel termination board. Data termination eliminates reflections at the
end of the DMX data run. Turn on DMX termination by sliding the switch to END in the last panel/
device that is physically connected to the DMX chain; for other devices, the switch should be in the
middle (OFF) position.
Installation
The graphic on the left illustrates DMX termination using screw terminal
If daisy-chaining to
another rack or
DMX device...
connectors that are intended for use with Belden 9729 cable (or
approved equivalent).
Screw terminal connectors are supplied in the DMX Preparation Kit w/
Screw Connector (part number 4100A1012) and shipped with your
Sensor IQ Breaker Panel.
Be aware that cable other than Belden 9729 may have a different color
code for its wire pairs.
The graphic on the right illustrates DMX
termination using IDC connectors that are
intended for use with Category 5 solid core
cable (or equivalent cable types). IDC
connectors are supplied in the Cat5
Preparation Kit w/ IDC Connector (part
number 4100A1013) and shipped only
when ordered separately.
Use a second connector on the DMX Pass-
Thru if daisy-chaining to another panel or
DMX device.
33