netvox RA0708 User Manual page 7

Wireless ph sensor
Hide thumbs Also See for RA0708:
Table of Contents

Advertisement

Report Configuration Example:
Description
Device
Config
ReportReq
Config
RA07 Series
ReportRsp
R726 Series
ReadConfig
R727 Series
ReportReq
ReadConfig
ReportRsp
(1) Configure RA0708 device parameters MinTime = 30s, MaxTime = 120s (120>30*1+10)
Downlink: 0105001E00780000000000
Device returns:
8105000000000000000000 (configuration is successful)
8105010000000000000000 (configuration failed)
(2) Read RA0708 device parameters
Downlink: 0205000000000000000000
Device returns:
8205001E00780000000000 (device current parameter)
Example for MinTime/MaxTime logic:
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime
Sleeping(MinTime)
Wakes up and collects data
REPORTS 3.6V
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value.
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x05
0x09
0x0D
0x02
MinTime
0x82
(2bytes Unit:s)
Wakes up and collects data
REPORTS 3.6V
NetvoxPayLoadData
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
MaxTime
(2bytes Unit:s)
MaxTime
Sleeping(MinTime)
Wake up and collects data
REPORTS 3.6V
6
Reserved
(5Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
(5Bytes,Fixed 0x00)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R72608Ra0708y

Table of Contents