Download Print this page

netvox RA0716A User Manual

Indoor multi-function environment sensor

Advertisement

Quick Links

RA0716A
Model:
Indoor Multi-Function Environment Sensor
Indoor Multi-function Environment Sensor
User Manual
Firmware:V1.1
Hardware:V0.4

Advertisement

loading

Summary of Contents for netvox RA0716A

  • Page 1 RA0716A Model: Indoor Multi-Function Environment Sensor Indoor Multi-function Environment Sensor User Manual Firmware:V1.1 Hardware:V0.4...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction................................2 2. Appearance................................. 3 4.Set up Instruction.................................4 4.1 Join Into Lora Network............................ 4 4.2 Function Key..............................4 4.3 Activation................................. 4 4.5 Data Report...............................5 5. Restore to Factory Setting............................5 6. Installation.................................. 6 7. Important Maintenance Instruction..........................6 8.
  • Page 3: Introduction

    Introduction RA0716A is a ClassA type device based on the LoRaWAN open protocol of Netvox and is compatible with the LoRaWAN protocol. RA0716A is unmasked for indoor inspection. RA0716A is connected to a variety of sensors. As detectors for PM2.5, temperature and humidity, the values collected by the sensor are reported to the corresponding gateway.
  • Page 4: Appearance

    2. Appearance Figure8 RA0716A PM2.5 and temperature and humidity sensor and battery box (subject to the actual object)
  • Page 5: Set Up Instruction

     Easy set up and installation 4.Set up Instruction 4.1 Join Into Lora Network RA0716A is powered by 8 sections of ER14505 lithium batteries and can communicate with the gateway. RA0716A needs to be added to the gateway network first. Operations are as follows: (1) After power-on, the un-networked device will automatically scan the network.
  • Page 6: Restore To Factory Setting

    3. The RA0716A device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, RA0716A can also perform the report according to the cycle time of the TxPeriod value; and at a certain time, the report period is ReportMaxTime or TxPeriod, depending on which cycle time is configured last time.
  • Page 7: Important Maintenance Instruction

    ug/m for more than 50% time of the year, or a concentration of more than 500 ug/m for more than 20% time of the year. The consistency of the sensor may decrease, possibly due to internal dust accumulation. The data is too high. 7.