netvox RA0708 User Manual page 5

Wireless ph sensor
Hide thumbs Also See for RA0708:
Table of Contents

Advertisement

Function Key
Press and hold for 5 seconds
Press once
Low Voltage Threshold
Low Voltage Threshold
Restore to Factory Setting
Instruction
Operation
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
The device is in the network: the green indicator flashes once and the device sends a data
report
The device is not in the network: green indicator remains off
10.5 V
RA0708_R72608_RA0708Y has a network information memory function when power-down.
This function is turned off by default, that is, it will be re-joined every time it is powered on.
This function can be turned on by the ResumeNetOnOff command.
At this time, each time the power is rewritten, the last network joining information will be
recorded (including saving the network address information assigned to it, etc., if you want to
join a new network, you need to perform a factory resetting operation first.)
It will not be re-joined the previous network.
1. Press and hold the button for 5 seconds and release (the binding button is released when the
LED flashes), and the
LED flashes for 20 times.
2. The device will automatically restart to re-joining.