Menu 3.2.3 Tank method

During practical flow calibration the tank is partly emptied through the
nozzles. Whilst emptying, the display calculates the quantity emptied on
the basis of the actual calibration value (PPU). The quantity displayed is
compared with the quantity actually dosed.
This can be according to the tank contents level indicator or by weight
difference before and after. The quantity displayed is corrected to read
the quantity actually dosed.
Method
1. Place the tank on level ground and fill it up with water until the
level reaches a unique mark on the tank contents level indicator,
e.g. 1000 litres.
2. Open all boom sections.
3. Go to menu [3.2.3 Tank method] and switch the main ON/OFF to
ON.
4. Engage the PTO. The display unit will then begin to count the
volume being emptied through the nozzles.
5. When, for example, 600 litres have been emptied out, as shown by the tank contents level indicator, disengage the PTO
and switch the main ON/OFF to OFF.
6. Press
.
7. Correct the volume shown on the display with the navigation keys to read the volume shown on the tank contents
level indicator.
8. Press
to save.
7 - Menu 3, Calibration
3.2.3
FLOW
Tank method
3.2.3
TANK METHOD
Sprayed
0 L
47