Diagnostic Data - YASKAWA VIPA FM 050-1BB30 Manual

System slio counter module eco 2x32bit
Table of Contents

Advertisement

Deployment

Diagnostic data

4.5 Diagnostic data
Overview
Name
Bytes
ERR_A
1
MODTYP
1
ERR_C
1
ERR_D
1
CHTYP
1
NUMBIT
1
NUMCH
1
CHERR
1
CH0ERR...
8
CH7ERR
DIAG_US
4
MODTYP Module informa-
tion
CHTYP Channel type
NUMBIT Diagnostic bits
54
So this module does not support process interrupts, the diagnostics data serve for infor-
mation about this module.
DS - Record set for access via CPU, PROFIBUS and PROFINET. The access happens
by DS 01h. Additionally the first 4 bytes may be accessed by DS 00h.
IX - Index for access via CANopen. The access happens by IX 2F01h. Additionally the
first 4 bytes may be accessed by IX 2F00h.
SX - Subindex for access via EtherCAT with Index 5005h.
More can be found in the according manual of your bus coupler.
Function
reserved
Module information
reserved
reserviert
Channel type
Number diagnostics bits per channel
Number channels of the module
reserved
reserved
µs ticker
Byte
Bit 7 ... 0
0
n
Bit 3 ... 0: Module class
1000b: Function module
n
Bit 4: set at channel information present
n
Bit 7 ... 5: reserved
Byte
Bit 7 ... 0
0
n
Bit 6 ... 0: Channel type
76h: Channel type
Bit 7: reserved
n
Byte
Bit 7 ... 0
0
Number of diagnostics bits of the module per channel
(here 00h)
Default
DS
00h
01h
18h
00h
00h
76h
00h
02h
00h
00h
00h
HB300 | FM | 050-1BB30 | en | 20-40
VIPA System SLIO
IX
SX
2F01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah ... 11h
13h