Demounting 8X Periphery Modules - YASKAWA VIPA FM 050-1BB30 Manual

System slio counter module eco 2x32bit
Table of Contents

Advertisement

VIPA System SLIO
Shield attachment

2.9 Demounting 8x periphery modules

Proceeding
Exchange of an electronic
module
HB300 | FM | 050-1BB30 | en | 20-40
1
Shield bus carrier
2
Shield bus (10mm x 3mm)
3
Shield clamp
4
Cable shield
To attach the shield the mounting of shield bus carriers are necessary. The shield bus
carrier (available as accessory) serves to carry the shield bus to connect cable shields.
1.
Each System SLIO 8x periphery module has a carrier hole for the shield bus carrier.
Push the shield bus carrier, until they engage into the module. With a flat mounting
rail for adaptation to a flat mounting rail you may remove the spacer of the shield
bus carrier.
2.
Put your shield bus into the shield bus carrier.
3.
Attach the cables with the accordingly stripped cable screen and fix it by the shield
clamp with the shield bus.
1.
Power-off your system.
2.
For the exchange of a electronic module, the electronic module may be pulled for-
ward after pressing the unlocking lever at the lower side of the module.
3.
For installation plug the new electronic module guided by the strips at the lower side
until this engages to the terminal module.
ð Now you can bring your system back into operation.