Deployment; Fast Introduction - YASKAWA VIPA FM 050-1BB30 Manual

System slio counter module eco 2x32bit
Table of Contents

Advertisement

VIPA System SLIO
4

Deployment

4.1 Fast introduction

Counter range
Address areas
Input area
Output area
HB300 | FM | 050-1BB30 | en | 20-40
Limits
Lower counter limit
Upper counter limit
The maximum counter frequency is 400kHz.
At CPU, PROFIBUS and PROFINET the input area is embedded to the corresponding
address area.
IX - Index for access via CANopen
SX - Subindex for access via EtherCAT with Index 6000h + EtherCAT-Slot
More can be found in the according manual of your bus coupler.
Addr.
Name
+0
CV_I
+4
CV_II
+8
CSTS_I
+10
CSTS_II
At CPU, PROFIBUS and PROFINET the output area is embedded to the corresponding
address area.
IX - Index for access via CANopen
SX - Subindex for access via EtherCAT with Index 7000h + EtherCAT-Slot
More can be found in the according manual of your bus coupler.
Addr.
Name
+0
CCTRL_I
+2
CCTRL_II
Valid range of values
31
-2 147 483 648 (-2
31
+2 147 483 647 (2
Bytes
Function
4
Counter 0:
Counter value
4
Counter 1:
Counter value
2
Counter 0:
Counter status
2
Counter 1:
Counter status
Bytes
Function
2
Counter 0:
Control word
2
Counter 1:
Control word
Deployment
Fast introduction
)
-1)
IX
5400h/s
5400h/s+1
5402h/s
5402h/s+1
IX
5602h/s
5602h/s+1
SX
01h
02h
03h
04h
SX
01h
02h
47

Advertisement

Table of Contents
loading

Table of Contents