Internal Tempo; Active At Start; Knob Mode; Control In - Elektron Analog Heat MKII User Manual

Stereo analog sound processor
Hide thumbs Also See for Analog Heat MKII:
Table of Contents

Advertisement

6.3.1 INTERNAL TEMPO

Sets the internal tempo. The tempo range is 30 – 300 BPM. This tempo controls the speed of the LFO.
The Analog Heat MKII can also be set to respond to MIDI clock sent from external devices. If the device
is synced from either MIDI Clock or Overbridge, the Internal Tempo setting is locked from editing, and
this parameter instead shows the sync source together with the currently active (external) tempo. For
more information, please see "6.6.1 SYNC" on page 20.
You can also use tap tempo. To tap a tempo setting, highlight INTERNAL TEMPO in the
SETTINGS menu, and then press and hold the [SETTINGS] key and tap the [YES] key in a
steady rhythm. The average tempo of the taps calculates after four consecutive taps. By
continuing tapping, the average tempo keeps on updating.

6.3.2 ACTIVE AT START

Sets if Analog Heat MKII is in Active Mode or not when it is turned on.

6.3.3 KNOB MODE

Sets how the knobs on the panel affect the parameters. When you load a preset, the knobs positions
typically don't match their parameter values.
• JUMP immediately sets the value to the current knob position.
• In CATCH mode, turning the knob do not change the parameter value until the knob position match-
es the presets stored value.
You can see the current value of the parameter in the screens title bar while you turn the knob.

6.4 CONTROL IN

6.4.1 CONTROL IN A

• CONTROL MODE
Sets the port mode to adjust to different kinds of input signals. There are four modes: CV (Control
Voltage), EXPR (Expression Pedal), FOOTSW (Footswitch) and OFF.
• CV ZERO LEVEL (Available when mode is set to CV.)
Sets the Volt level at which CV modulation amount is zero. A control input level equal to this setting
corresponds to zero modulation. (-5.50 V–+5.50 V).
• CV MAX LEVEL (Available when mode is set to CV.)
Sets the Volt level at which CV modulation amount is max. A control input level equal to this setting
corresponds to full modulation. (-5.50 V–+5.50 V).
• EXPRESSION LEARN (Available when mode is set to EXPR.)
Sets the highest and lowest limit of the control input level.
CONTROL IN A/B
pedal to
min position. Press YES to save settings.
• REVERSE DIRECTION (Available when mode is set to EXPR.)
Reverses the direction of how the Expression pedal sends control input signals.
• FOOTSW DEST (Available when mode is set to FOOTSW.)
Sets the destination of the control input from the Footswitch. The options are: TEMPO, ACTIVE,
PRESET +, PRESET -, ENV TRIG
• FOOTSWITCH LEARN (Available when mode is set to FOOTSW.)
Sets the high and low limit of the control input level. When in this setting, connect the Footswitch
pedal to CONTROL IN A/B. Press YES and then press the Footswitch pedal a couple of times.
Press YES to save settings.
• REVERSE DIRECTION (Available when mode is set to FOOTSW.)
Reverses the direction of how the Footswitch pedal sends control input signals.
YES and then move the expression pedal first to max and then to
. Press
When in this setting, connect the Expression
6. THE SETTINGS MENU
17

Advertisement

Table of Contents
loading

Table of Contents