6. Loosen each retaining screw and insert the wire into the appropriate slot (see Figure 15 on 
7. Tighten the retaining screws.
8. Reinstall the Power/Alarm Connector in the Electronics Module.
9. Tie wrap and route these wires as shown above. This prevents the connector from coming 
10.Reinstall the rubber grommet when closing the Electronics Module. 
64187712G2-5C
page 29 and Table
5 on page 29).
Back of Electronics Module

Figure 18. Power/Alarm Connector Installed

loose when the Electronics Module is closed.
7
6
5
4
3
2
1
Power/Alarm Connector
Tie Wrap wires as shown
Note: Even though there are brackets to
position the Euro-Connector wires,
we recommend not using them. Use
of these brackets can "bind" the wires
when the Electronics Module is closed.
Rubber Grommet