ADTRAN Total Access 300 Series Installation And Maintenance Manual page 19

Gige sfu ont with rf overlay and swrd powering
Hide thumbs Also See for Total Access 300 Series:
Table of Contents

Advertisement

NOTE
•  The main feed is optical and therefore not classified as any type of port as
defined in Appendix B of GR‐1089‐CORE, Issue 4.
•  The Total Access 300 Series SFUs are designed to operate with nominal
operating voltage of 12 VDC and a minimum operating voltage of 10.5
VDC. The Total Access 300 Series will not be damaged by any steady state
voltage between 10.5 VDC and 15.0 VDC in magnitude.
•  Power supply input and output conductors of equipment which are
outside of the building, are intended to be less that 100 feet and have
adequate clearance from power and lightning conductors in accordance
with NEC 725 and 800. Final acceptance of the Listed equipment
installation will ultimately be up to the local Authority Having Jurisdiction
(AHJ).
64187712G2-5C
Safety and Regulatory Compliance
7