Figure 14. Ont Ground Connection - ADTRAN Total Access 300 Series Installation And Maintenance Manual

Gige sfu ont with rf overlay and swrd powering
Hide thumbs Also See for Total Access 300 Series:
Table of Contents

Advertisement

5. Route the #6 ground wire 12" below finished grade by the shortest and most direct route 
6. Attach the #6 ground wire to the side of the subscriber premise with stainless steel half 
7. Clean the MGN connector with emery cloth to insure a stable connection.
8. Coat the connection with a metal corrosion preventative.
9. Connect the ground wire to the ground lug and tighten.
10.Attach a Warning Ground Tag to this grounding connection.
64187712G2-5C
Splice Housing
(1187770G1)

Figure 14. ONT Ground Connection

to the AC power ground system (MGN) of the customer premise free of any sharp bends. 
(Refer to the "Alternative Grounding Method" on the following page if MGN is not 
available).
moon clamps or tie‐wrap the ground to the riser conduit of the buried fiber cable drop. 
When using tie‐wraps wait until the Local Power Source (LPS) wire run has been installed 
and tie‐wrap both the #6 ground wire and the LPS wire run to the riser conduit of the 
Buried Fiber drop.