Total Access 300 GigE SFU ONT with RF Overlay and SWRD Powering Installation and Maintenance Guide
Table 4 shows the Configuration Codes for the Total Access 5000 362S.
!
WARNING
The 10/100/1000 Base‐T port(s) and POTS are classified as Type 4 as defined in
Appendix B of GR‐1089‐CORE, Issue 4, and is suitable for connection to intra‐
building or unexposed wiring or cabling only. Do not metallically connect
these ports to interfaces that connect to the Outside Plant (OSP) or to the OSP
wiring. The 10/100/1000 Base‐T ports and POTS are designed for use as an
intra‐building interface only (Type 4 ports as described in GR‐1089‐CORE,
Issue 4) and require isolation from exposed OSP cabling. The addition of
Primary Protectors is not sufficient protection to connect this interface
metallically to OSP wiring.
C
CAUTION
This product contains a Class 1 Laser module which complies with 21 CFR
1040.10 and 1040.11.
!
CAUTION
•  This equipment must be connected to a known, reliable earth ground at all
times during installation and service. Refer to the National Electrical Code
(NEC) and state/local codes for details on grounding requirements. A 6
AWG copper ground conductor shall be used to connect the equipment to
earth ground.
•  Per GR‐1089‐CORE the Total Access 300 Series SFU ONTs are designed and
intended for installation as part of a Common Bonding Network (CBN).
The Total Access 300 Series SFU ONT are not designed nor intended for
installation as part of an Isolated Bonding Network (IBN).
•  Per GR‐1089‐CORE Section 9, the SFU ONTs do not have an internal DC
connection between 12V and frame ground. 
•  The Total Access 300 Series chassis frame ground terminal must be
connected to an earth ground to ensure the ONT SFU is properly
grounded.
•  The Total Access 300 Series SFU ONTs are NRTL Listed to the applicable
UL safety standards. The Total Access 300 Series SFU ONTs meet or exceed
all the applicable requirements of Telcordia GR‐63‐CORE. 
•  The Total Access 300 Series SFU ONTs are intended for deployment in the
Outside Plant (OSP) at locations where the NEC applies (for example,
Customer Premises) and is intended to be installed by trained service
personnel.
6

Table 4. Configuration Codes

Configuration Codes
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
Input
Output
F
C
A
64187712G2-5C