List of parameters
Parameter
P00
Hydraulic confi guration
P01
Gas type
P02
System type
P03
Ignition ramp time
P04
Delay to prevent water hammer
P05
CH OFF time
P06
Post-circulation pump in CH
P07
Post-circulation pump in DHW
P08
Minimum power DHW
P09
Minimum power CH
P10
Maximum power CH
P11
Maximum power DHW
P12
Not applicable
P13
Outdoor sensor coeffi cient
P14
MIN setpoint CH
P15
MAX setpoint CH
P16
MAX setpoint DHW
P17
Maximum circulator speed
P18
Starting delay CH
P19
Enable gas valve trim
P20
Not applicable
P21
Not applicable
P22 (if P21=1)
Not applicable
P23 (if P21=1)
Not applicable
P24 (if P21=1)
Not applicable
b
The boiler parameters must only be set or modifi ed by professionally qualifi ed personnel. The manufacturer shall not be liable for malfunctions or damage caused by improper
confi guration of the appliance.
mode.
By pressing the RESET button for 10 seconds, you can exit the installer mode.
If no key is pressed within 15 minutes, parameter mode is automatically exited.
4.12
Info menu (In)
b
Access to the menu is not allowed with the boiler in the OF state.
Access the Info menu as follows:
- Press the RESET button for 10 seconds to enter confi guration mode. "tS" begins to fl ash
on the display.
- Press the CH+ or CH- buttons to navigate the menu and select the Info menu (In).
10
Description
Unit of
Default
Range
measure
--
2
2..5
0 NG
--
0..1
1 LPG
--
0
0..1
Min
1
0..30
Sec
2
0..20
Min
3
0..10
Min
3
0..10
Min
1
0..10
%
0
0..100
%
0
0..100
%
100
0..100
%
100
0..100
--
1
0..1
--
0
0..30
25
°C
20..40
30
45
40..55
°C
80
40..88
60
45..75
°C
--
--
%
100
60..100
Sec
0
0..199
--
0
0..1
°C
5
3..9
--
0
0..1
rpm x10
140
140..180
1000
140
100
rpm x10
100..140
100
110
rpm x10
110..140
115
- Press MODE to confi rm, the display shows the fi rst Info parameter.
- Press the CH+ or CH- buttons to select the parameter number.
- The parameter value is shown alternately with the parameter number (2 seconds each).
Info list
1
DHW sensor temperature
2
CH sensor temperature
Notes
2 = combi boiler
3 = not applicable
4 = not applicable
5 = not applicable
0 = methane (G20)
1 = GPL (G31)
0 = HT (high temperature)
1 = not used
0 = disabled
0 = disabled
0 = disabled
0 = disabled
0 = disabled
0 = disabled
0 = disabled
if P02 = 1 not used
if P02 = 0 (HT)
if P02 = 1 not used
if P02 = 0 (HT)
if P00 = 2
if P00 ≠ 2
not used
0 = disabled
Not applicable to this model
0 = disabled
if P01= 0 (G20)
if P01= 1 (G31)
if P01 = 0 (G20)
if P01= 1 (G31)
if P01= 0 (G20)
if P01 = 1 (G31)
+
-
°C
0..125
°C
0..125