Connecting and wiring of the vision sensor

1.
Verify that the 24 V DC power supply being used is unplugged and not receiving power.
2.
Optionally, connect the I/O or serial wires to an appropriate device (for example, a programmable controller).
3.
Attach the power and I/O breakout cable's [24 V DC] (Red wire) and [GND] (Black wire) to the corresponding terminals
on the power supply.
4.
Connect the power and I/O breakout cable's M12 connector to the vision sensor's power, I/O and RS-232 connector.
5.
Turn on the 24 V DC power supply switch.
Precautions
• When connecting the vision sensor and programmable controller, simultaneously turn on the vision sensor and
programmable controller, or first turn on the programmable controller.
• Cut unused wires or protect them with insulating materials. Keep all bare wires separated from the 24 V DC wire.
• All cable connectors are "keyed" to fit the connectors on the vision sensor. Do not force the connections or damage may
occur.
1 THE SLMP SCANNER CONNECTION
6
1.1 Introduction

Advertisement