Check Inspection Results - Mitsubishi Electric MELSENSOR VS20 Connection Manual

Vision sensor, fa sensor
Hide thumbs Also See for MELSENSOR VS20:
Table of Contents

Advertisement

2.
Set the trigger.

Check inspection results

Check inspection results.
(a)
1 THE SLMP SCANNER CONNECTION
24
1.6 Checking Operations
(b)
(c)
 To enable the trigger from the
programmable controller, turn "ON" the
"Network Trigger Enable" bit (D1000.0)
of the control bit block.
When the "Network Trigger Enable" bit
(D1000.0) is "OFF", the vision sensor
does not operate even though the
trigger is ON.
 Turn "ON" the "Trigger" bit
(D1000.1) of the control bit block.
(a) Inspection Completed: The vision
sensor is triggered and an search
result is output. As the inspection
result, the format output data set with
the SLMP Scanner of In-Sight Explorer
is output.
(b) D1015 = Pattern_1 PASS
(c) D1016 = Pattern_1 FAIL
(d) D1017 = Inspection count
When the inspection is completed, the
"Inspection Completed" bit (D1002.9)
of the status bit block changes
(toggles).
To set the trigger to the vision sensor
again, turn "ON" D1000.1.
(d)